AOR AR8200 Spezifikationen Seite 136

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 142
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 135
136
It is possible to load a band scope directly from EM8200 external memory for immediate display on
the LCD. Use the key sequence to access the band scope load
menu, the legend “B-SCOPE LOAD” will be displayed.
the key to toggle the memory selection between INTERNAL “INT” and EXTERNAL
EXT”, the default is “EXT”. Select “EXT” then use the main dial or ï ð keys to select one of the
EM8200 memory locations (0, 1, 2 or 3). to recall the trace directly to the LCD for
immediate viewing.
&Note: For further information regarding the band scope, please refer to
section 15
of this
manual.
(19) Trouble shooting
Should the AR8200 appear to act strangely, check out the following suggestions to see if the problem
can be overcome. Failing this, switch off the AR8200, disconnect any external power connection and
remove one battery from the radio (if you have batteries fitted). Wait for at least 30 seconds then re-fit
the battery (if in use) or re-connect the external power and switch the radio on again with a of
the key.
Check to see if the problem has cleared.
19-1 Soft reset of microprocessor
If removing power and switching the AR8200 off / on does not help, try a soft reset of the microprocessor.
Soft reset is achieved by powering-up the radio with the key held, do not release the
key until the opening message has performed and a frequency is displayed in 2VFO mode.
All scan & search environments are cleared, bank link is set off and the receiver frequency will be set to
88.000 MHz for both VFO-A and VFO-B. The beep will be enabled and set to default as will lamp and
LCD contrast. All memory and search bank data will be intact.
19-2 Other trouble shooting suggestions
AR8200 will not power on. Check that the set is connected to external power (12V d.c.) or that
batteries are fitted and are fully charged.
There is no audio. It may simply be that the squelch is closed or volume is turned down. and
hold the key and adjust the volume to a comfortable level. Ensure that no external loudspeaker,
headphone or earphone is in use. Check that the band scope is not in operation.
AR8200 display is strange and there is no audio. Check that the band scope is not in operation,
.
Section 19, 19-1, 19-2
Seitenansicht 135

Kommentare zu diesen Handbüchern

Keine Kommentare