AOR AR8000 Spezifikationen Seite 1

Stöbern Sie online oder laden Sie Spezifikationen nach Empfänger AOR AR8000 herunter. AOR AR8000 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 115
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
AR8000 operating manual
1
(1) Introduction & accessories
Thank you for purchasing THE NEW CONCEPT AOR AR8000 World Band
Wide Band all mode receiver.
This operating manual is divided into many sections and presented in a logical
order assuming that it will be read section by section following the examples.
However, if you are familiar with the operations of modern mulit-function
receivers you may proceed directly to section 6. Many phrases are repeated
through the manual, while this may make the text a little repetitious, it should
provide clear instructions if you refer directly to a specific section.
Every effort has been made to make this manual correct and up to date. Due
to continuous development of the receiver and by error or omissions anomalies
may be found and this is acknowledged.
Most apparent faults are usually due to accidental misoperation of the receiver,
carefully read all of the manual before deciding to return the receiver for repair.
Although carefully designed, this receiver (like all receivers) suffers from a
degree of internal noises known as spurii. They are a product of the receiver’s
circuitry and do not represent a fault.
This manual is protected by copyright AOR LTD 1994. No information
contained in this manual may be copied or transferred by any means without
the prior written consent of AOR LTD. AOR and the [AOR] logo are trade
marks of AOR, LTD. All other trade marks and names acknowledged. E&OE.
© 1994 AOR LTD.
Operating manual Conventions
Where text appears in [SQUARE BRACKETS] the keys are to be pressed
exactly as shown.
For example: [1] [4] [5] [ENT]
Means press the 1 key followed by the 4 key followed by the 5 key followed by
the enter key.
The arrow keys to the lower left of the keypad are referred to as UP / DOWN or
[UP] [DOWN] keys.
Words contained in speech marks “2VFO” refer to indications displayed on the
Liquid Crystal Display.
Where memory banks etc are empty the indication “- - -” is often displayed.
Sections of
“italic text”
indicate an advanced function or facility only available
when in EXPERT rather than NEWUSER status, please refer to section 6-3 for
further information.
Seitenansicht 0
1 2 3 4 5 6 ... 114 115

Inhaltsverzeichnis

Seite 1 - AR8000 operating manual

AR8000 operating manual1(1) Introduction & accessoriesThank you for purchasing THE NEW CONCEPT AOR AR8000 World BandWide Band all mode receiver.Th

Seite 2

AR8000 operating manual104-4 NiCads and chargingBefore operating, charge the internal NiCad batteries using the suppliedcharger for approximately 16 h

Seite 3

AR8000 operating manual100The default is set to 0.3 seconds. The acceptable range is 0.0 to 4.9seconds. For solid operation on 900MHz a value of 0.5

Seite 4

AR8000 operating manual10118-1 Setting the RS232 parametersThe RS232 parameters may be altered using the “REMOTE” option in theCONFIGURATION menu. Th

Seite 5

AR8000 operating manual102(19) Clone (copy) data between two AR8000 receiversIt is possible to clone (copy) selected or ALL data from one AR8000 to a

Seite 6

AR8000 operating manual103Make sure that the EXPERT status is selected, if not use the UP/DOWN key tomove the cursor alongside the “NEWUSER” option an

Seite 7

AR8000 operating manual104Both “A” & “B” VFO frequencies will reset to 80.000 MHz and mode/step willbe set to AUTO.Search/scan bank linkage and s

Seite 8

AR8000 operating manual105transmissions (you can usually remove the aerial to determine this).Alternatively the AR8000 (like all receivers) will produ

Seite 9

AR8000 operating manual106“FREQ ERROR”This error message will be displayed if you attempt to key in a frequencyoutside of the acceptable range of 0.1

Seite 10

AR8000 operating manual107WA7000 wide band active whip aerialCompact aerial designed for installation where space is a problem. TheWA7000 is active o

Seite 11

AR8000 operating manual108Long wire aerialsFor shortwave reception a random length of long wire approximately 10 to 20metres in length forms a good co

Seite 12

AR8000 operating manual109As a compromise it may be worth making up a dipole aerial for a band ofparticular interest and have a VHF-UHF discone plus s

Seite 13

AR8000 operating manual11(frequencies such as 1.215 MHz = 1215 kHz). If signal strength appears weak,try rotating the receiver as the bar aerial is d

Seite 14

AR8000 operating manual110Coaxial cablesWhen constructing dipole aerials or connecting VHF aerials 50 OHM coaxialcable should be used. For shortwave

Seite 15

AR8000 operating manual111Typical usable coverage starts from about 25 MHz and extends continuouslyto 500 MHz 1300 MHz or even 2000 MHz. The coverage

Seite 16

AR8000 operating manual112This provides a screen for potential incoming interference and passes anynoise down the cable away from the receiver and tow

Seite 17

AR8000 operating manual113If the transmitted frequency is too high for to be reflected by the ionosphere,or the angle too steep, transmissions will s

Seite 18

AR8000 operating manual114You will note that large areas of the Earth’s surface lays between the point oftransmission and reflection, in this area th

Seite 19

AR8000 operating manual115* Specifications subject to change without notice due to continuousdevelopment of the receiver. E&OE.(24) Specification

Seite 20

AR8000 operating manual12the ATU when changing frequency. An ATU of this type has no active circuitryso is known as a passive device.Active desktop l

Seite 21

AR8000 operating manual135-2 EAR - Earphone / speaker connectionThis 3.5mm mono socket permits connection to an external earphone, headsetor speaker o

Seite 22

AR8000 operating manual145-5 PWR / VOL - On/Off switch and volume controlThe combined volume control and power switch is located onthe top face of the

Seite 23

AR8000 operating manual15

Seite 24

AR8000 operating manual16switchable for use in locations of low level lighting.The basic operational description of each key is as follows:[SRCH] - se

Seite 25

AR8000 operating manual17revert to VFO mode.[2-VFO] [A=B] - twin VFO / equalise memory /manual search keyThe AR8000 receiver has a 2 VFO system being

Seite 26

AR8000 operating manual18should a permanently busy channel be encountered. The UP and DOWN keysmay be used to force the receiver to continue searchin

Seite 27

AR8000 operating manual19[2] [B] [STEP] Numeric 2 / Bank B / STEP keyThis key acts as a numeric 2 when entering frequencies via the keypad.In search,

Seite 28

AR8000 operating manual21-1 Accessories supplied4 x AA internal high capacity rechargeable NiCad batteriesMains chargerDC power lead with cigar lighte

Seite 29

AR8000 operating manual20[6] [F] [S PROG] Numeric 6 / Bank F / Search programThis key acts as a numeric 6 when entering frequencies via the keypad.In

Seite 30

AR8000 operating manual21[9] [I] [DEL] Numeric 9 / Bank I / Data deleteThis key acts as a numeric 9 when entering frequen- cies via thekeypad.In sear

Seite 31

AR8000 operating manual22and the legend “SET P.WORD” is displayed on the first line of the LCD.If the numbers “0000” are displayed then no password is

Seite 32

AR8000 operating manual23NEWUSER / EXPERTThe default setting is NEWUSER (new user), this is the initial recommendedsetting. If EXPERT status has not

Seite 33

AR8000 operating manual24SCAN list.To toggle the status of select scan, press [FUNC] [PASS] again while in M.REmode.Select scan only scans those speci

Seite 34

AR8000 operating manual25

Seite 35

AR8000 operating manual26When in 2ndF setting, the side panel [FUNC] key need only be momentarilypressed then released before pressing a second keypad

Seite 36

AR8000 operating manual27Side panel - right hand side5-13 DC 12V Charging / external power connectionThis is a standard 1.3mm dual concentric DC socke

Seite 37

AR8000 operating manual28Rear caseThe battery compartment cover (which is located to the lower section of therear case) may be removed using a downwar

Seite 38

AR8000 operating manual29

Seite 39

AR8000 operating manual36-6 Correcting incorrect frequencies after input ... 356-7 Changing a frequency using the UP/DOWN keys .. 366-8 Ch

Seite 40

AR8000 operating manual30(6) Basic manual operation of the receiverOperating manual conventionsWhere text appears in [SQUARE BRACKETS] the keys are to

Seite 41

AR8000 operating manual31In normal use, the squelch control should be rotated clockwise until thebackground noise is just cancelled. This is known as

Seite 42

AR8000 operating manual32the operators preferences.When in FUNC setting, the side panel [FUNC] key must be pressed and heldwhile a second keypad optio

Seite 43

AR8000 operating manual336-4 Entering a frequency through the keypad - VFO (MANUAL) MODE& changing from VFO “A” to VFO “B” and [A=B]The AR8000 re

Seite 44

AR8000 operating manual34Entering a frequency using the numeric keypadExample of frequency entry 145.800 MHzPress [1] [4] [5] [.] [8] [ENT]There is no

Seite 45

AR8000 operating manual35right of the “MHz” position, this is to ensure easy recognition of frequencieswhich are often listed as “kHz” in frequency gu

Seite 46

AR8000 operating manual36Key in [2] to correct the current incorrect display (which is showing 81.8MHz rather than 82.8 MHz). Alternatively use the [

Seite 47

AR8000 operating manual37The speed of tuning may be increased by a factor of x10 while the “F” functionlegend is displayed (by using the [FUNC] key).6

Seite 48

AR8000 operating manual38For example, select 118.000 MHz [1] [1] [8] [ENT] then select a 9 kHz stepsize [FUNC] [2] choose “9.00” by rotating the [DIAL

Seite 49

AR8000 operating manual391.08 kHz (which are not divisible by 50 Hz), the last digit will not be accepted somay be corrected simply by typing [5].In f

Seite 50

AR8000 operating manual413 SEARCH ... 7613-1 Manual search ...

Seite 51

AR8000 operating manual40being 71.018750 MHz). The receiver is now tuning in 12.5 kHz steps with astep offset of +6.25 kHz.Note: The STEP OFFSET is a

Seite 52

AR8000 operating manual41AMAmplitude Modulation - Used by broadcast services throughout the world onmedium wave and shortwave. AM is also used by VHF

Seite 53

AR8000 operating manual42Small tuning steps of 50 Hz or 100 Hz should be used for tuning in LSB andother similar modes USB & CW.The AR8000 being a

Seite 54

AR8000 operating manual43attenuator is OFF.The selection of attenuator may also be programmed into memory channelsand when defining program search.Ple

Seite 55

AR8000 operating manual44To deactivate the bandscope, repeat the key sequence [FUNC] [7] or press the[2VFO], [SRCH] or [SCAN] keys.(7) Memory banks &a

Seite 56

AR8000 operating manual45During the manufacture and testing of the receiver, various test frequencies areentered into the receiver’s memory banks so t

Seite 57

AR8000 operating manual46If you are happy with the alphanumeric description press [ENT] and the displaywill return to VFO mode.At any time you may abo

Seite 58

AR8000 operating manual47Note: If you have activated the PASSWORD protection, it is not possibleto access memory banks a, b, c, d, e, f, g, h, i, j un

Seite 59

AR8000 operating manual48[9] [2] [.] [7] [ENT] to select the desired frequency, the mode and stepsize will be automatically set by the AR8000 micropro

Seite 60

AR8000 operating manual49“COPY-MODE” to indicate that a sub menu has been selected.The cursor will be positioned over the memory bank identifier (LETT

Seite 61

AR8000 operating manual5(3) Major featuresGeneralAt first glance the AR8000 in it’s static form may look no different to anymodern hand-held wide rang

Seite 62

AR8000 operating manual508-4 MEMORY CHANNEL COPY - alternative method using memory recallOther AR8000 facilities may be manipulated in order to achiev

Seite 63

AR8000 operating manual51The third line will alternate between MODE and STEP while the fourth line willalternate between TXT and FREQUENCY so that eas

Seite 64

AR8000 operating manual52Enter memory dataSwitch On. Press [2VFO] to enter 2VFO mode.Type in the first frequency [8] [8] [.] [3] [ENT]. Press and hol

Seite 65

AR8000 operating manual53Press [FUNC] [8] to access the “SET EDIT-CH” menu.Move the cursor to the left of the “SWAP-MODE” option using the UP/DOWNkeys

Seite 66

AR8000 operating manual54Example of memory channel editingLet’s assume that you wish to EDIT the contents of memory channel “A00”which for example may

Seite 67

AR8000 operating manual55The standard options are: 0.05 kHz (50 Hz), 0.1 kHz (100 Hz), 0.2 kHz (200Hz), 0.5 kHz (500 Hz), 1.00 kHz, 2.00 kHz, 5.00 kH

Seite 68

AR8000 operating manual568-8 Deleting memory channels and banksIt is possible to delete memory channels on an individual basis or delete awhole memory

Seite 69

AR8000 operating manual57The top line of the LCD will display “MEMO-DATA” the second line will display“DELETE” and the fourth line will display “BANK

Seite 70

AR8000 operating manual58When the password facility is first used the numbers “0000” are displayed toindicate that no password has been set and all ba

Seite 71

AR8000 operating manual599-4 If you forget your passwordShould you forget the password and become locked out, you may reset themicroprocessor by holdi

Seite 72

AR8000 operating manual62VFOTwin VFO frequencies (A & B) may be displayed onthe LCD simultaneously, one providing a stand-byfrequency available fo

Seite 73

AR8000 operating manual60Another special form of scanning is “PRIORITY” where a special channel(default to “A00”) is scanned for activity every five s

Seite 74

AR8000 operating manual61Keep your memory banks tidy - for best scan speedIn order to achieve the maximum scanning speed, it is advisable to keep alls

Seite 75

AR8000 operating manual62The memory bank identifier (such as “A”) will be displayed on the left of thethird line of the LCD and memory bank “A” will b

Seite 76

AR8000 operating manual63on the top left of the LCD, if it is not in SCAN mode then press [2VFO] [FUNC][SCAN] which should achieve SCAN regardless of

Seite 77

AR8000 operating manual64when only the selected banks which contain data will be scanned.* Refer to section 10-12 for further SCAN options which are a

Seite 78

AR8000 operating manual65The receiver will display a memory channel, mode, frequency, text and scanPASS status.If the desired memory channel to be PAS

Seite 79

AR8000 operating manual66It is strongly recommended that NEWUSER mode is used duringfamiliarisation of the AR8000, use EXPERT status only if you havef

Seite 80

AR8000 operating manual67Either use the [DIAL] to change the value or key in a two digit number throughthe numeric keypad. [0] [0] is accepted as 0.0

Seite 81

AR8000 operating manual68Either use the [DIAL] to change the value or key in a two digit number throughthe numeric keypad. [0] [0] is accepted as 00

Seite 82

AR8000 operating manual69(11) SELECT SCAN - special “select scan list” overviewWhile scanning memory banks, you may decide that some memory channelsa

Seite 83

AR8000 operating manual7Free search - the receiver will pause on a busy channel for a predeterminedlength of time and will resume searching after the

Seite 84

AR8000 operating manual7011-1 SELECT SCAN - while in SCAN MODE (tagging and un-tagging)While the receiver is scanning it will stop on active frequenci

Seite 85

AR8000 operating manual71Each time the sequence [FUNC] [PASS] is keyed then the SELECT SCANstatus “s” is toggled so that the channel may be “tagged” (

Seite 86

AR8000 operating manual7211-4 SELECT new “SELECT SCAN” channels using the menuTo access the “SELECT SCAN” EDIT menu place the receiver into VFO modeth

Seite 87

AR8000 operating manual7311-5 DELETE individual “SELECT SCAN” channelsTo access the “SELECT SCAN” EDIT menu place the receiver into VFO modethen press

Seite 88

AR8000 operating manual74(12) Priority operationThe PRIORITY feature enables you to carry on scanning, searching ormonitoring while the AR8000 checks

Seite 89

AR8000 operating manual75To cancel priority operation press [FUNC] [4], the legend “P” will be removedfrom the top line of the LCD.12-2 Changing PRIOR

Seite 90

AR8000 operating manual76(13) SEARCH - search banks and frequency passThe AR8000 has a SEARCH mode whereby an upper and lower frequencylimit may be d

Seite 91

AR8000 operating manual77Searching using the mode of WFM may not be possible in certain frequencybands due to the level of background noise and adjace

Seite 92

AR8000 operating manual78To restart the manual search process from the startTo start the manual search from the original frequency press [2VFO] to ret

Seite 93

AR8000 operating manual79The legend “BANK” is displayed on the left of the third line with a memorylocation to the right. Either key in the desired m

Seite 94

AR8000 operating manual8Copy (CLONE) between two AR8000 receiversThe stored memory and search data may be transferred from one set toanother using an

Seite 95

AR8000 operating manual8013-2 Program search banksIt is possible to save parameters of frequency, mode, step step offset andcomment into any of the 20

Seite 96

AR8000 operating manual8113-3 Program search facilities & saving “active” frequencies to memoryStarting manual searchto initiate PROGRAM SEARCH pr

Seite 97

AR8000 operating manual82The legend “BANK” is displayed on the left of the third line with a memorylocation to the right. Either key in the desired m

Seite 98

AR8000 operating manual83SELECT PROGRAM SEARCH BANK FOR PROGRAMMING: To access theSEARCH PROGRAM menu press [FUNC] [6]. The legend “SRCH PROG” willb

Seite 99

AR8000 operating manual84Rotate the [DIAL] to indicate “25.00” on the third line of the LCD to select a 25kHz step size.If EXPERT status has been sele

Seite 100

AR8000 operating manual8513-5 SEARCH - outline introduction to facilities available in defaultNEWUSER statusDuring program search, the receiver tunes

Seite 101

AR8000 operating manual86the search bank identifier via the numeric keypad (“A”, “B”, “C” etc). This isthe usual way in which program search banks wo

Seite 102

AR8000 operating manual8713-8 Searching a program search bank which is not specified in BANKLINKIt is still possible to SEARCH a single deselected ban

Seite 103

AR8000 operating manual88To access the additional options of “SET SEARCH-SCAN”Once in EXPERT status five additional options are available. To access

Seite 104

AR8000 operating manual89HOLD - To resume search when HOLD has been set, press either the [UP]or [DOWN] keys. “FREE search” will be ignored if SEARCH

Seite 105

AR8000 operating manual9AR8000 from the aerial and switch the set Off.4-2 Looking after your receiverAlways keep the receiver free from dust and water

Seite 106

AR8000 operating manual90To accept the changes to FREE search press [ENT] to return to SEARCHmode.Alternatively you may move to the next option (LEVEL

Seite 107

AR8000 operating manual91direction program search was previously using.Delete program search bank data while in VFO modeFirst place the receiver into

Seite 108

AR8000 operating manual9214-2 FREQUENCY PASS (lockout) using the “FREQ PASS” edit menuNew frequencies may be manually added to the frequency pass list

Seite 109

AR8000 operating manual9314-4 Changing (editing) a PASS frequencyIt is possible to edit a frequency contained in the pass list.To edit a frequency in

Seite 110

AR8000 operating manual94This may be useful when carefully evaluating frequency bands using manualsearch and specifically selecting pass frequencies b

Seite 111

AR8000 operating manual95(15) AUTO STORE - automatic memory write fromprogram search modeThe AR8000 features an Automatic memory write facility.AUTO

Seite 112

AR8000 operating manual96The top line of the LCD will display “MEMO-DATA” the second line will display“DELETE” and the fourth line will display “BANK

Seite 113

AR8000 operating manual97First place the AR8000 into “M.RE” mode by switching on the receiver andpressing the [SCAN] key once (unless it is in SCAN mo

Seite 114

AR8000 operating manual98DELAY: This parameter determines how soon the receiver will become“dormant (then cycle)” and is timed from when the squelch l

Seite 115

AR8000 operating manual99(17) SPECIAL functionsThere are five “special” programmable functions available so that you mayfurther optimise the receiver

Kommentare zu diesen Handbüchern

Keine Kommentare